FlyingFiber’s multi purpose distribution cable provide 2 – 12 fibers, 900μm tight buffer fiber, aramid yarn, PVC, LSZH, OFNR Jacket. Comply with Standard YD/T 1258.4-2005, ICEA-596, GR-409, IEC794, etc; and meet the requirements of UL approval for OFNR.
No. of Fiber |
2F |
4F |
6F |
8F |
10F |
12F |
Cable Diameter (mm) |
4.1±0.25 |
4.8±0.25 |
5.1±0.25 |
5.6±0.25 |
5.8±0.25 |
6.2±0.25 |
Cable Weight (kg/km) |
11.0 |
18.4 |
22 |
24 |
27 |
31 |
TBF Diameter |
900±50μm |

Tensile Strength |
Long Term |
200N |
Short Term |
660N |
Crush Resistance |
Long Term |
300N/100mm |
Short Term |
1000N/100mm |
Bending Radius |
Dynamic |
20×D (Cable Diameter) |
Static |
10×D (Cable Diameter) |
|
|
50/125μm |
62.5/125μm |
G.652 |
G.655 |
Attenuation(+20℃) |
@850nm |
≤3.5dB/km |
≤3.5dB/km |
|
|
@1300nm |
≤1.5dB/km |
≤1.5dB/km |
|
|
@1310nm |
|
|
≤0.45dB/km |
≤0.50dB/km |
@1550nm |
|
|
≤0.30dB/km |
≤0.50dB/km |
Bandwidth (Class A) |
@850nm |
≥500MHz·km |
≥200MHz·km |
|
|
@1300nm |
≥1000MHz·km |
≥600MHz·km |
|
|
Numerical Aperture |
0.200±0.015NA |
0.275±0.015NA |
|
|
Cable Cut-off Wavelength λcc |
|
|
≤1260nm |
≤1480nm |
Attenuation at temperature cycling Δα(-20℃~+85℃) |
@1300nm |
≤0.50dB/km |
≤0.50dB/km |
|
|
@1550nm |
|
|
≤0.20dB/km |
≤0.20dB/km |
Transport Temperature |
-20℃~+60℃ |
Storage Temperature |
-20℃~+60℃ |
Installation Temperature |
-5℃~+50℃ |
Operating Temperature |
-20℃~+60℃ |